A low-temperature air-cooled water chiller is a machine that circulates coolant to lower equipment temperatures.
Refrigeration System
Dual independent refrigeration circuits support continuous operation under variable load conditions.
Compressor staged control adjusts cooling output according to system demand.
Electronic expansion valve regulates refrigerant flow based on real-time temperature feedback.
Air-cooled condenser system achieves heat rejection through forced airflow without external water systems.
Engineering Selection Parameters
Cooling capacity: multiple standard models available for different industrial load requirements.
Temperature range: selectable low-temperature operating range depending on process requirement.
Power supply: 220V / 380V / 415V / 440V / 480V industrial standards supported.
Refrigerant: R404A / R448A / R449A selectable based on temperature target and compliance needs.
System configuration: air-cooled or water-cooled structure with optional VFD control integration.
Principle
Refrigerant absorbs heat in the evaporator, is condensed, and throttled back to low-temperature vapor, forming a continuous cooling cycle.


Technical Specifications

Application
Laser equipment cooling systems
Chemical process temperature control
Medical and laboratory low-temperature environments
Industrial testing and simulation systems
Production equipment heat dissipation systems
Factory Verification Protocol
Cooling performance is tested under simulated load conditions to verify stable low-temperature operation.
Refrigeration system undergoes pressure holding and leakage detection before shipment.
Electrical system is tested for overload protection, phase stability, and control response accuracy.
Full unit continuous operation testing is completed prior to delivery with recorded operating data.
Compliance Standards
Manufactured under ISO 9001 quality management system.
Electrical system designed according to IEC 60204-1 industrial safety standard.
Refrigeration system references ISO 5149 and EN 378 safety standards.
Pressure system verification follows ASME-based integrity testing methodology (project-dependent).
Project Engineering Support
System selection based on cooling load and process temperature requirements.
Complete technical documentation including piping layout and electrical diagrams.
Remote commissioning support during installation and startup phase.
Spare parts supply and maintenance guidance for long-term operation stability.
FAQ
Q1: What installation environments are supported?
Designed for outdoor air‑cooled operation without external cooling towers.
Q2: How is temperature controlled?
Automated control system with expansion valves regulates refrigerant flow.
Q3: Can the unit run 24/7?
Yes - configured with safety and control systems for continuous operation.
Q4: What protective devices are included?
A: Includes high/low pressure, overcurrent, phase protection, and overheat monitors.
Hot Tags: low temperature air cooled chiller, China low temperature air cooled chiller manufacturers, factory