Product overview
Cold Water Chiller for Air Cooler is an air-cooled scroll chiller designed to supply chilled water to industrial air coolers and process cooling systems. It delivers stable temperature control with dual refrigeration circuits, integrated water pump, and shell-and-tube evaporator.
Features
- 36 kW cooling capacity with dual scroll compressors ensures stable chilled water supply for medium-duty industrial air cooling applications.
- Two independent refrigeration circuits improve operational reliability and allow partial-load running to reduce energy consumption.
- Shell-and-tube evaporator provides efficient heat exchange and better resistance to fouling in industrial water systems.
- Integrated cast-iron water pump (7 m³/h, 2 bar) simplifies installation and reduces external piping costs.
- Comprehensive protection system including phase loss, overload, high/low pressure, overheat, and anti-freeze protection minimizes downtime.
- Branded components such as Sanyo compressors, Emerson expansion valves, and LS/CHNT electrical parts ensure long-term serviceability.
datasheet
|
Item |
Specification / Supplier |
|
|
Cooling capacity |
Model |
AYD-12A |
|
kw |
36 |
|
|
Power input |
kw |
11.62 |
|
Power Supply |
380V-3N-50HZ |
|
|
Temp Outlet (℃) |
10 |
|
|
refrigerant control |
Expansion valve |
|
|
Refrigeration circle |
two |
|
|
refrigerant |
R407C |
|
|
Dimension(mm)L*W*H |
1550*780*1700 |
|
|
Compressor |
Style |
Scroll |
|
Quantity(set) |
2 |
|
|
Compressor Power(kw) |
9.24 |
|
|
Condenser |
Style |
Fin type with copper coil |
|
Fan Quantity(set) |
2 |
|
|
Air Volume(m3/h) |
12600 |
|
|
Evaporator |
Style |
Shell and Tubes |
|
Cold water flow(m3/h) |
6.2 |
|
|
Pipe size(DN) |
40 |
|
|
Cast-iron Water Pump(kw) |
1.5(7m3/h,2bar) |
|
|
Protector Device |
1.Phase protector 2.Fan overload protector 3.High/low voltage protector 4.overheat protector 5.Anti-freeze protector |
|
|
Unit Weight(kg) |
520 |
|
|
Main Parts |
||
|
Compressor |
Sanyo |
|
|
Condenser |
Anyda |
|
|
Evaporator |
Jindian |
|
|
Electronic |
LS/ Chnt |
|
|
Expansion Valve |
Emerson |
|
|
Control System |
Punp |
|
Remarks: The cooling capacity is based on ambient temp 30C, inlet/outlet temp 12/7C.
Structure of the cold water chiller



Applications
- Food Processing - Cooling air coolers in cold rooms and blast chillers
- HVAC Industry - Supplying chilled water to air handling units
- Pharmaceutical Manufacturing - Temperature control for cleanroom cooling
- Chemical Industry - Process air cooling and ventilation systems
- Plastics Industry - Cooling production workshops and drying systems
- Logistics Warehousing - Refrigerated storage and air cooler support
- Beverage Industry - Cooling fermentation and packaging areas
- Electronics Manufacturing - Environmental temperature control
Optional Configurations
- Stainless Steel Water Tank - Improved corrosion resistance for demanding water quality
- PLC Touch Screen Controller - Advanced monitoring and remote diagnostics
- Modbus RS485 Communication - Integration with BMS and central control systems
- High Ambient Design - Suitable for operation in up to 50°C environments
- Low Temperature Version - Outlet water temperature down to 0°C with glycol
- Variable Frequency Drive (VFD) - Reduces starting current and improves energy efficiency
- Alternative Refrigerants - R410A or R134a available based on regional regulations
- Custom Pump Head and Flow Rate - Selected according to project piping resistance
OEM & Customization (OEM/ODM)
- Custom cooling capacities available from 3 kW to 500 kW.
- Voltage options include 220V, 380V, 415V, 460V, and 60Hz configurations.
- Private label branding for nameplates, manuals, and packaging.
- Custom control logic and communication protocols supported.
- Refrigerant selection based on destination market requirements.
- Pump, tank, and piping materials can be modified for specific applications.
- Export packaging can be adapted to distributor and project requirements.
MOQ: 1 unit for standard models; 5 units for OEM private label orders.
Quality Assurance
- Incoming Quality Control (IQC) for compressors, valves, electrical components, and heat exchangers.
- Copper piping pressure test using dry nitrogen to verify leak-tightness.
- Refrigeration system vacuum dehydration before refrigerant charging.
- Electrical safety tests including insulation resistance and grounding continuity.
- Water circulation and pump performance verification.
- Full-load functional testing under simulated operating conditions.
- Protection system verification for all safety devices.
- Final Quality Control (FQC) including appearance inspection and packing check.
Factory Strength
- Factory Size: 8,000+ m² manufacturing facility dedicated to industrial refrigeration equipment.
- Production Equipment: CNC sheet metal machines, tube expanders, vacuum charging stations, and computerized testing platforms.
- Engineering Team: 15+ refrigeration and control engineers with extensive project experience.
- Production Capacity: Over 1,500 chillers and cooling systems annually.
- Export Experience: More than 10 years serving distributors and OEM customers in Europe, Southeast Asia, the Middle East, and South America.
certifications

FAQ
Hot Tags: cold water chiller for air cooler, China cold water chiller for air cooler manufacturers, factory