Split Air Water Chiller System
video
Split Air Water Chiller System

Split Air Water Chiller System

1.Low noise indoor
2.Save indoor space
3.Longer lifespan
Send Inquiry
Description

Product overview

 

The Split Air Water Chiller System is a two-circuit air-cooled industrial chiller with a split design that separates the condensing unit and indoor hydraulic module. It supplies chilled water for stable process cooling.

 

Features

 

  • 50.96 kW cooling capacity with dual refrigeration circuits ensures stable operation and allows partial-load running to reduce energy consumption.
  • Two Sanyo scroll compressors provide reliable cooling performance with fewer moving parts and lower maintenance requirements.
  • Split system design separates the outdoor condensing section from the indoor water module, reducing indoor heat and noise.
  • Shell-and-tube evaporator offers high heat transfer efficiency and better resistance to scaling in industrial applications.
  • Integrated 1.5 kW water pump and 200 L insulated tank minimize installation time and simplify system commissioning.
  • Comprehensive safety protections including phase loss, overload, high/low pressure, overheat, and anti-freeze protection improve equipment longevity and reduce downtime.

 

 

Item

Specification / Supplier

Cooling capacity

Model

AYD-20A

kw

50.96

Power input

kw

20.84

Power Supply

380V-3N-50HZ

Temp Outlet (℃)

7

refrigerant control

Expansion valve

Refrigeration circle

two

refrigerant

R22

Dimension(mm)L*W*H

1950*910*1700

Compressor

Style

Scroll

Quantity(set)

2

Compressor Power(kw)

16.9

Condenser

Style

Fin type with copper coil

Fan Quantity(set)

2

Air Volume(m3/h)

21000

Evaporator

Style

Shell and Tubes

Cold water flow(m3/h)

10.16

Pipe size(DN)

50

Water Pump(kw)

1.5(11m3/h,2bar)

Water Tank(L)

200

Protector Device

1.Phase protector

2.Fan overload protector

3.High/low voltage protector

4.overheat protector

5.Anti-freeze protector

Unit Weight(kg)

790

Main Parts

Compressor

Sanyo

Condenser

Anyda

Evaporator

Jindian

Electronic

LS/ Chnt

Expansion Valve

Emerson

Pump

Mina

Control System

Punp

Remarks: The cooling capacity is based on condensing temp 50C, inlet/outlet temp 12/7C.

 

 

applications

 

  • Plastics Industry - Injection molding machine cooling
  • Laser Industry - Laser source and cutting head cooling
  • HVAC Industry - Secondary chilled water supply
  • Food Processing - Process water temperature control
  • Chemical Industry - Reactor and mixing vessel cooling
  • Pharmaceutical Industry - Batch process cooling
  • Printing Industry - Press roller cooling
  • Electronics Industry - SMT and soldering equipment cooling

 

 

Optional Configurations

  • Refrigerant Options - R407C, R410A, or R134a available to meet regional regulations.
  • Power Supply Options - 220V/380V/415V/460V, 50Hz or 60Hz.
  • Stainless Steel Water Tank - Improves corrosion resistance for demanding water conditions.
  • Plate Heat Exchanger - Compact alternative for clean water applications.
  • Variable Speed Pump - Adjusts flow rate to reduce energy consumption.
  • Microcomputer PLC Controller - Supports Modbus RS485/BMS communication.
  • Remote Condenser Installation Kit - Customized piping length and control settings for split projects.
  • Glycol Solution Design - Adapted for low ambient or anti-freeze requirements.

All configurations can be customized according to cooling load, ambient temperature, water quality, and installation layout.

 

 

OEM & Customization (OEM/ODM)

  • Private label branding on unit casing, controller interface, nameplates, and packaging.
  • Cooling capacity customization from 5 kW to 500 kW based on project requirements.
  • Refrigerant selection to comply with local environmental regulations.
  • Customized split piping lengths and refrigerant charge for remote condenser installation.
  • Special materials such as stainless steel tanks, titanium evaporators, and anti-corrosion coatings.
  • Control system customization including PLC, touch screen, and BMS integration.
  • Export packaging options including plywood cases and container loading plans.

MOQ: 1 unit for standard models; 5 units for private label OEM orders.

 

 

Quality Assurance

  1. Incoming inspection of compressors, electrical components, heat exchangers, and valves.
  2. Copper tubing pressure holding test and welding quality inspection.
  3. Refrigeration system nitrogen leak test.
  4. Vacuum dehydration to remove moisture and non-condensable gases.
  5. Accurate refrigerant charging by electronic weighing.
  6. Electrical safety testing including insulation resistance and grounding continuity.
  7. Water circulation and hydraulic performance testing.
  8. Full-load factory run test with recording of cooling capacity, current, and pressure.
  9. Final appearance inspection and packaging verification before shipment.

 

 

Factory Strength

  • Factory Size: 8,000+ m² manufacturing facility with dedicated assembly and testing areas.
  • Production Equipment: CNC sheet metal machines, tube bending equipment, vacuum charging systems, and performance test benches.
  • Engineering Team: 15+ refrigeration and electrical engineers for design and technical support.
  • Production Capacity: 100+ chillers per month with standardized production procedures.
  • Export Experience: 10+ years supplying OEM and ODM chillers to Europe, Southeast Asia, the Middle East, and South America.

 

 

FAQ

1. What is the difference between a split chiller and an integrated air-cooled chiller?
A split chiller separates the condensing unit and indoor hydraulic module, which reduces indoor heat and allows more flexible installation.
 
2. Can the condenser and indoor module be installed far apart?
Yes. Refrigerant piping length can be customized based on project layout and ambient conditions.
 
3. What certifications can be provided?
CE, ISO9001, and other project-specific certifications are available upon request.
 
4. What is the lead time for OEM orders?
Standard models usually ship within 7–15 working days, while customized OEM orders typically require 20–35 working days.

 

 

Hot Tags: split air water chiller system, China split air water chiller system manufacturers, factory

You Might Also Like
Send Inquiry

(0/10)

clearall