A water-cooled air cooler is an industrial cooling unit used to deliver chilled air to indoor spaces.
Cooling & Control Performance
Cooling water temperature is maintained within 5–32°C operating range.
System supports multi-setpoint temperature adjustment via PLC control.
Continuous operation maintains stable output without temperature fluctuation under steady load.
Safety & Operating Protection
High/low pressure, overload, short circuit, phase loss, and overheat protection are integrated into the system.
Pump interlock and fire damper linkage ensure coordinated shutdown during abnormal conditions.
Independent compressor protection reduces single-point failure risk in long operation cycles.

Internal structure and overall dimensions of the unit.

System layout and refrigeration cycle overview.
Compliance & Testing Validation
Electrical Safety Standard Compliance
Testing conducted according to IEC 60204-1 for industrial electrical equipment safety.
Thermal Performance Verification
Cooling capacity validated under controlled full-load testing conditions following ISO-based thermal evaluation methods.
Airflow & Pressure Testing Standard
Air handling performance tested under AMCA airflow measurement methodology for volume and pressure accuracy.
System Stability Validation
Continuous operation testing confirms stable output under extended runtime cycles without abnormal deviation.
Technical Specifications

Application
1.Localized Industrial Cooling
Used for direct air cooling in manufacturing equipment zones and process areas where heat dissipation is needed.
2.Process Temperature Regulation
Applied in cooling processes such as soldering, reflow ovens, and similar heat-generation equipment operations.
3.Space Cooling in Utility Areas
Used in machine rooms, workshops, and other utility spaces requiring controlled cold air supply.
4.Supplementary HVAC Cooling
Can support larger HVAC systems by providing targeted cooling to specific zones or high-load points.
Installation & Operational Support
Installation Documentation
Provides piping layout and electrical wiring diagrams for system integration.
Commissioning Assistance
Supports system startup and parameter configuration during initial operation stage.
Operation Training
Covers startup sequence, monitoring points, and alarm handling procedures.
Maintenance Support
Provides spare parts supply and technical support for long-term system operation.
FAQ
Q1: What information should I provide for a quote?
To prepare a detailed quote, please provide the required outlet air temperature, cooling capacity, and power supply details.
Q2: Does the unit include all necessary components?
Yes. Typical models include fan, compressor, evaporator, condenser, and necessary protective devices.
Q3: What refrigerants are supported?
Common refrigerants include R22, R407C, and R134A, depending on model specifications.
Q4: How is the unit controlled?
Control options range from built-in microcomputer controllers to integration with external systems via available interfaces.
Q5: What protective features are included?
Protective devices such as phase protection, fan overload protection, and high/low voltage protection are typically provided.
Hot Tags: water cooled air cooler, China water cooled air cooler manufacturers, factory