Air-cooled water chillers are industrial refrigeration units utilizing air-exchange technology to provide stable closed-loop cooling for temperature-sensitive industrial processes.
Cooling Working Principle
Air and water flow in opposite directions inside the tower
Heat is transferred from water to air through contact exchange
Hot circulating water enters from the top and is evenly distributed
Air enters from the side and passes through the fill media
Cooled water is collected at the bottom basin for recirculation
Working principle
The closed cooling tower runs on a sealed internal loop with external spray cooling and forced-air heat exchange.
It integrates internal circulation, spray water, airflow exchange, and control units into a closed-loop cooling system.

Tower Structure & Components
Steel Frame Structure
Hot-dip galvanized steel frame provides structural support and corrosion resistance
Fill Media System
PVC wave-type fill creates multi-layer water film heat exchange channels
Fan System
Axial fan system provides stable airflow driving force
Water Distribution System
Rotary spray system ensures uniform water distribution over fill media
Water Collection System
Bottom basin collects cooled water for circulation reuse
Maintenance Access Design
Reserved access openings for inspection and maintenance operations
Technical Specifications
|
No. |
Item |
Unit |
Specs |
|
|
Summary |
||
|
1 |
Name |
Closed Type Cooling Tower |
|
|
2 |
Model |
AYD-200T |
|
|
3 |
Cooling Capacity |
kcal/h |
1000000 |
|
4 |
Design Pressure |
Mpa |
1.0 |
|
5 |
Test Pressure |
Mpa |
1.2 |
|
6 |
Cooling Water Flow |
m3/h |
200 |
|
7 |
Water Inlet Temp |
℃ |
37 |
|
8 |
Water Outlet Temp |
℃ |
32 |
|
9 |
Flying Water Loss(%) |
≤0.005% |
|
|
10 |
Water Pipe Size |
mm |
DN150*2 |
|
11 |
Connection Size(supply/overflow/drain) |
mm |
DN32 |
|
12 |
Net Weight |
kg |
3200 |
|
13 |
Running Weight |
Kg |
6800 |
|
14 |
Dimension(L x W x H) |
mm |
5800*2000*4500 |
|
|
Fan System |
||
|
1 |
Each Unit Fan Qty |
pcs |
3 |
|
2 |
Driving Mode |
direct |
|
|
3 |
Fan Air Volume |
m3/h |
240000 |
|
4 |
Motor Water Proof Class |
IP55 |
|
|
5 |
Motor Insulation Class |
F |
|
|
6 |
Single Fan Motor Power |
kw |
7.5 |
|
7 |
Power Supply |
3PH/415V.50Hz |
|
|
8 |
Air Duct Material |
Hot Dip Galvanized |
|
|
|
Sprinkler System |
||
|
1 |
Pump Qty |
unit |
1 |
|
2 |
Water Pump Type |
Spray Pump |
|
|
3 |
Pump Body Material |
Cast-iron |
|
|
4 |
Motor Insulation Class |
F |
|
|
5 |
Single Pump Flow |
m3/h |
200 |
|
6 |
Single Pump Power |
kw |
5.5 |
|
7 |
Lift |
m |
6 |
|
|
Heat Exchange Tube |
||
|
1 |
Heat Exchange Tube Material |
304 # |
|
|
2 |
Coil Thickness |
mm |
0.8 |
|
3 |
Diameter |
mm |
19 |
|
4 |
Manifold Material |
304 # |
|
|
5 |
Connection way for manifold and exchange tube |
welding |
|
|
6 |
Heat Exchange Coil Design Pressure |
Mpa |
1.0 |
|
7 |
Heat Exchange Coil Test Pressure |
Mpa |
1.2 |
|
8 |
Flange |
PN10 |
|
|
|
Main Parts Material |
||
|
1 |
Spray Tube Material |
PVC |
|
|
2 |
Sprinkler |
ABS |
|
|
3 |
Water Collector |
PVC |
|
|
4 |
Water Supply Way |
Float Ball Valve |
|
|
5 |
Fastener |
Q235 |
|
|
6 |
Structure Material |
Zinc Al Magnesium Plate |
|
|
7 |
Structure Anti Corrosive Way |
Zinc Al Magnesium Plate |
|
|
8 |
Structure Anti Corrosive Thickness |
mm |
0.06 |
|
9 |
Outer Panel Thickness |
mm |
2 |
|
10 |
Outer Panel Anti corrosive Way |
Zinc Al Magnesium Plate |
|
|
11 |
Outer Casing Material |
Zinc Al Magnesium Plate |
|
Manufacturing & Quality Validation
International Performance Standard
Thermal performance verified according to CTI STD-201 testing methodology
Quality Management System
Manufacturing process operated under ISO 9001 quality management system
Structural Manufacturing Standard
Designed and manufactured in compliance with GB/T 7190-2008 cooling tower standard
Fan System Testing
Vibration level, rotational stability, and current load performance tested
Water Distribution Testing
Spray uniformity and circulation performance verified under simulated operation
Full Unit Operational Test
Complete tower load simulation test conducted before shipment
Structural Inspection
Welding quality, galvanized coating thickness, and dimensional accuracy inspected
Project Cooperation Support
Selection Support
Cooling capacity and temperature difference calculation support for system design
Engineering Drawing Support
Foundation drawings, installation drawings, and piping reference diagrams provided
Delivery Coordination
Supports phased production and delivery based on project schedule
Spare Parts Support
Long-term supply of fan, fill media, motor, and water distribution components
Engineering Supply Capability
Project-Based Production
Manufacturing organized according to project specifications instead of stock models
Batch Delivery Capability
Supports phased delivery for large-scale industrial projects
Component Traceability
Key components such as fans, motors, and fill media are traceable by batch and supplier source
Engineering Coordination
Supports technical communication for parameter confirmation and structural alignment
Applications
1.Process Water Cooling Loops
Cooling of closed-circuit process water in industrial systems.
2.Equipment Cooling Circuits
Cooling loops for machine tools, compressors, and process equipment.
3.Independent Cooling Systems
Heat rejection units for standalone or packaged cooling systems.
Custom Engineering Services
Environmental Adaptation
Special anti-corrosive coatings or high-temp modifications for coastal or extreme climates.
Smart Integration
RS485/Modbus protocol support for seamless connection to centralized automation systems.
Modular Scalability
Flexible parallel configurations allow for cooling capacity expansion alongside production growth.
FAQ
Q1: What data is needed to select a cooling tower model?
Provide circulating water flow rate, inlet/outlet temperature, and ambient conditions.
Q2: How does a closed cooling tower differ from an open one?
It uses a closed circuit with tube coils, isolating the process fluid from ambient air.
Q3: Is water treatment required?
Closed loop reduces contamination and scaling risk, but periodic maintenance and water quality monitoring are recommended.
Q4: Can it support non-water fluids?
Some designs support oil and other fluids through appropriate heat exchanger selection.
Hot Tags: closed water circuit cooling tower, China closed water circuit cooling tower manufacturers, factory